NURALAM, MUHAMAD (2025) ANALISIS OPTIMASI SISTEM KENDALI CONTROL VALVE PADA GLAND SEAL WATER CEP (CONDENSATE EXTRACTION PUMP) DI PLTU PAITON UNIT 1 & 2. S1 thesis, Universitas PGRI Madiun.
|
Text
Halaman depan.pdf Download (1MB) |
|
|
Text
Abstraks.pdf Download (719kB) |
|
|
Text
BAB I.pdf Download (1MB) |
|
|
Text
BAB II.pdf Download (4MB) |
|
|
Text
BAB III.pdf Restricted to Repository staff only Download (1MB) |
|
|
Text
BAB IV.pdf Restricted to Repository staff only Download (1MB) |
|
|
Text
BAB V.pdf Download (439kB) |
|
|
Text
Daftar Pustaka.pdf Download (772kB) |
|
|
Text
Lampiran with scan.pdf Restricted to Repository staff only Download (1MB) |
Abstract
The Paiton Unit 1 & 2 Steam Power Plant (PLTU) is one of the providers of electricity in Indonesia. One of the vital components in the water-steam cycle is the Condensate Extraction Pump (CEP). The gland seal water system in the CEP functions to prevent leakage between the shaft and housing by maintaining water pressure. This study aims to analyze the reliability of the gland seal water pressure control system before and after it was modified into an integrated automatic system to the Distributed Control System (DCS) with the addition of a smart positioner and pressure transmitter. The research was conducted quantitatively by collecting actual pressure data for one month at one-day intervals. The variables analyzed included gland seal water pressure, DCS demand signals, and actuator feedback. Data analysis used descriptive statistics, independent-samples t-tests, and Pearson correlations. The t-test results showed that the integrated control system was able to maintain the pressure close to the set point of 5.00 kg/cm² with a p-value of 0.01 (< 0.05), indicating a significant difference compared to the previous system. The correlation test between the demand signal and the valve control position feedback shows a very strong relationship (r = 0.999), which indicates an accurate control response. In addition, control accuracy increased by 62.8% after the DCS integrated system was implemented. This study concludes that DCS integration significantly improves the accuracy and reliability of the gland seal water control system at the CEP in Paiton Power Plant Units 1 & 2.
| Item Type: | Thesis/Skripsi/Tugas Akhir (S1) |
|---|---|
| Kata Kunci: | Gland Seal System; Pressure Transmitter; Smart Positioner; DCS |
| Subjects: | T Technology > T Technology (General) T Technology > TJ Mechanical engineering and machinery T Technology > TK Electrical engineering. Electronics Nuclear engineering |
| Divisions: | Fakultas Teknik > Teknik Elektro |
| Depositing User: | MUHAMAD NURALAM MUHAMAD |
| Date Deposited: | 07 Oct 2025 07:06 |
| Last Modified: | 07 Oct 2025 07:06 |
| URI: | http://eprint.unipma.ac.id/id/eprint/5203 |
Actions (login required)
![]() |
View Item |
