ANALISIS KINERJA PLTS ROOFTOP 87,4 KWP SEBAGAI SUPLAI HYDROGEN PLANT BERDASARKAN PERFORMANCE RATIO (PR) DI PT PLN NUSANTARA POWER UP PACITAN

Prastya, Dharma Dwi (2026) ANALISIS KINERJA PLTS ROOFTOP 87,4 KWP SEBAGAI SUPLAI HYDROGEN PLANT BERDASARKAN PERFORMANCE RATIO (PR) DI PT PLN NUSANTARA POWER UP PACITAN. S1 thesis, UNIVERSITAS PGRI MADIUN.

[img] Text
HALAMAN DEPAN.pdf

Download (1MB)
[img] Text
ABSTRAK.pdf

Download (210kB)
[img] Text
BAB I.pdf

Download (213kB)
[img] Text
BAB II.pdf

Download (629kB)
[img] Text
BAB III.pdf
Restricted to Repository staff only

Download (428kB) | Request a copy
[img] Text
BAB IV.pdf
Restricted to Repository staff only

Download (335kB) | Request a copy
[img] Text
BAB V.pdf

Download (197kB)
[img] Text
DAFTAR PUSTAKA.pdf

Download (176kB)
[img] Text
LAMPIRAN.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy

Abstract

Dharma Dwi Prastya. 2026. Analysis of the Performance of 87.4 kWP Solar Power Plants as the Supply of H₂ Plant PT PLN NP UP Pacitan. Undergraduate Thesis. Study Program of Electrical Engineering, Faculty of Engineering, Universitas PGRI Madiun.. Advisors: (I) Irna Tri Yuniahastuti, S.Pd., M.Pd., (II) Ina Sunaryatiningsih S.T., S,Pd., M.T. This study aims to analyze the performance of the rooftop Solar Power Plant (PLTS) with a capacity of 87.4 kWp as the energy supply of the H₂ Plant at PT PLN Nusantara Power UP Pacitan. The research method used is a descriptive quantitative method with an approach to analyze the performance of the photovoltaic system based on actual operational data during the period June–October 2025. Performance evaluation was carried out using Reference Yield (YR), Final Yield (YF), and Performance Ratio (PR) parameters according to IEC 61724 standard, and compared with simulation results using PVsyst 7.4.8 software. The results of the study show that the solar PV system is able to support the energy needs of H₂ Plants with an average energy output of 316.11 kWh per month and an average energy export to the grid of 182.90 kWh per month. The average values of real YR, real YF, and real PR were 159.81 kWh/kW, 109.68 kWh/kWp, and 69.75%, respectively, while PVsyst simulation results showed values of 183.03 kWh/kW, 156.27 kWh/kWp, and 85.42%. The difference between actual and simulated results is influenced by variations in irradiance, environmental temperature, weather conditions, and system losses. Overall, the 87.4 kWp rooftop solar power plant at PT PLN Nusantara Power UP Pacitan has good performance and is suitable for use as an energy source to support the H₂ Plant's operations. Keywords: Rooftop PV System, Hydrogen Plant, PVsyst, Final Yield, Performance Ratio

Item Type: Thesis/Skripsi/Tugas Akhir (S1)
Kata Kunci: Rooftop PV System; Hydrogen Plant; PVsyst; Final Yield; Performance Ratio